MAINTENANCE & SUPERVISION
With LNG becoming increasingly viable and popular as a marine fuel,
E&CO continues to develop technical solutions that facilitate this trend
E&CO MAINTENANCE & SUPERVISION
E&CO can provide best manpower for customers’ request for site trouble shooting.
Planned maintenance and customer-focused supervision service is our pride for project success.
Timely manner of maintenance & supervision can make to prolong equipment operation time and maintenance period.
E&CO keeps strict HSE policy in terms of highly technical service and responsibility.
E&CO, we believe good service recreate customers’ value & profits.
A/S WORKS
- FGSS System (Storage part, Fuel gas supply part, Propulsion part)
- ISO Tank Container, Tank Lorry, Tank Trailer
- Cryogenic Tank & Pressure Vessel
- Site Construction, Erection, Piping, Fabrication, Electric, Extra Equipment etc.
VACUUMING WORKS
- Tank Vacuuming Works in Site
- Tank Vacuuming Works in Site
: Vacuuming work time shall depend on the tank status & environment condition
* Normal Vacuum ( Max. Vacuum 0.05 Torr ) : Centrifugal Pump
* High Vacuum ( Max. Vacuum 0.001 Torr ) : Diaphram Diffusion Pump
<Normal Vacuum Pump>
<High Vacuum Pump>
WELDING WORKS
- Plate & Piping
* Shielded Metal Arc Welding (SMAW)
* Gas Metal Arc Welding (GMAW)
* Gas Tungsten Arc Welding (GTAW)
* Flux Cored Arc Welding (FCAW)
* Submerged Arc Welding (SAW)
* Electro Gas Welding (EGW)
* Plasma Arc Welding (PAW)
* Stud Welding (SW)
PAINTING WORKS
- Shop and site work available
- Sanding and Short work
- 1ST, 2ND Epoxy Primer, Epoxy Paint work
- 3RD Urethane Paint work
- Fire Resisting Paint work available
- Painting work takes about 5 days (<30㎥) ~ 10 days (>30㎥)
PIPING & TUBING WORKS
- Stainless Steel, Duplex & Carbon Piping work available
- Available Size Range 6A (1/8") ~ 500A (20")
- Tube, Union, Elbo, Clamp Extra Equipment etc. work available
- Shop Fabrication work㎥)
INSULATION WORKS (perlite or MLI)
- Perlite works in both shop and site
- MLI work only in shop
- Perlite work takes about 7 days (<30㎥) ~ 14 days (>30㎥)
- MLI work takes about 14 days (20ft ~ 40ft)
<Perlite Insulation work>
<MLI Insulation work>
VALVES REPAIR WORKS
- Globe, Check, Gate, On-off, Control, Ball valves, and etc. repair work available
- Re-inspect safety valve (Popping test)
- Product and parts replaceable
SITE SUPERVISION
- Shop and site work available
- Sanding and Short work
- 1ST, 2ND Epoxy Primer, Epoxy Paint work
- 3RD Urethane Paint work
- Fire Resisting Paint work available
- Painting work takes about 5 days (<30㎥) ~ 10 days (>30㎥)